Introduction
The SVC4C countertop cooler vending machine by Seaga India is designed for small spaces, combining energy-efficient refrigeration and easy maintenance. This guide provides essential instructions for setup, operation, and troubleshooting.
Table of Contents
- Specifications
- Installation Guidelines
- Operating Instructions
- Maintenance and Cleaning
- Troubleshooting
1. Specifications
Physical Characteristics:
- Height: 470 mm
- Width: 620 mm
- Depth: 530 mm
- Net Weight: 28.5 kg
Refrigeration:
- Compressor: Hermetically sealed
- Refrigerant: R134a
- Condensate Tray: Self-evaporating
Electrical Requirements:
- Voltage: 230V AC ±10%, 50 Hz
- Running Amperage: 1A
Environmental Conditions:
- Operating Temperature: 18°C to 22°C
- Maximum Storage Temperature: 60°C
2. Installation Guidelines
- Site Preparation:
- Unpacking and Leveling:
- Electrical Setup:
- Initial Start-Up:
3. Operating Instructions
- Load the cooler evenly across the top and bottom shelves.
- Keep the door closed as much as possible to maintain cooling efficiency.
4. Maintenance and Cleaning
Defrosting:
- Typically not required due to the fixed thermostat cycle. If cooling efficiency decreases, turn off the unit to manually defrost.
Cleaning:
- Wipe the interior and exterior with a soft cloth and a solution of warm water and baking soda. Avoid using soap or detergent.
5. Troubleshooting
Common Issues:
Issue | Possible Cause | Solution |
Unit not running | No power or loose connection | Check power supply and secure connections. |
High internal temperature | Door left open, improper gasket seal, or poor placement | Close the door, fix gasket, and ensure proper ventilation. |
Unusual noise | Uneven leveling or loose components | Adjust legs or tighten screws. |
No cooling | Compressor or refrigerant issue | Contact technical support for assistance. |
For more immediate support, contact [email protected] or call +91-1276-268122.
Manual Access: Find the full manual here.