Introduction
The SVC4C countertop cooler vending machine by Seaga India is designed for small spaces, combining energy-efficient refrigeration and easy maintenance. This guide provides essential instructions for setup, operation, and troubleshooting.
Table of Contents
- Specifications
 - Installation Guidelines
 - Operating Instructions
 - Maintenance and Cleaning
 - Troubleshooting
 
1. Specifications
Physical Characteristics:
- Height: 470 mm
 - Width: 620 mm
 - Depth: 530 mm
 - Net Weight: 28.5 kg
 
Refrigeration:
- Compressor: Hermetically sealed
 - Refrigerant: R134a
 - Condensate Tray: Self-evaporating
 
Electrical Requirements:
- Voltage: 230V AC ±10%, 50 Hz
 - Running Amperage: 1A
 
Environmental Conditions:
- Operating Temperature: 18°C to 22°C
 - Maximum Storage Temperature: 60°C
 
2. Installation Guidelines
- Site Preparation:
 - Unpacking and Leveling:
 - Electrical Setup:
 - Initial Start-Up:
 
3. Operating Instructions
- Load the cooler evenly across the top and bottom shelves.
 - Keep the door closed as much as possible to maintain cooling efficiency.
 
4. Maintenance and Cleaning
Defrosting:
- Typically not required due to the fixed thermostat cycle. If cooling efficiency decreases, turn off the unit to manually defrost.
 
Cleaning:
- Wipe the interior and exterior with a soft cloth and a solution of warm water and baking soda. Avoid using soap or detergent.
 
5. Troubleshooting
Common Issues:
| Issue | Possible Cause | Solution | 
| Unit not running | No power or loose connection | Check power supply and secure connections. | 
| High internal temperature | Door left open, improper gasket seal, or poor placement | Close the door, fix gasket, and ensure proper ventilation. | 
| Unusual noise | Uneven leveling or loose components | Adjust legs or tighten screws. | 
| No cooling | Compressor or refrigerant issue | Contact technical support for assistance. | 