Introduction
The AMS Sensit I vending machine incorporates innovative Sensit technology for accurate product dispensing. This guide covers the essential aspects of setup, daily use, and troubleshooting, ensuring long-term reliability and customer satisfaction.
Specifications
Specification | Details |
Dimensions | Height: 72", Width: 39", Depth: 34" |
Weight | ~850 lbs. |
Power Requirements | 115V or 230V, 50/60 Hz |
Refrigeration | Factory-sealed R290 refrigerant system |
Technology | Sensit product detection system |
Selections | Configurable trays for snacks and beverages |
Key Features
- Sensit Detection Technology: Ensures reliable vending by confirming product delivery.
- Customizable Tray Layouts: Accommodates a wide variety of product sizes and configurations.
- Energy-Efficient Refrigeration: Maintains product freshness with reduced power consumption.
- Durable Build: Engineered for high-traffic environments.
Installation
Placement Guidelines
- Position the machine on a stable, level surface capable of supporting 1,200 lbs.
- Maintain proper ventilation clearances:
Electrical Connection
- Connect to a grounded outlet with the appropriate voltage (115V/230V).
- Avoid using extension cords or shared circuits.
Initial Setup
- Power on the machine and access the control menu.
- Calibrate the Sensit detection system to ensure proper product monitoring.
- Perform a diagnostic test to verify functionality.
Operation
Loading Products
- Unlock and open the machine door.
- Pull out the trays to access the product slots.
- Load items, ensuring proper alignment in the coil spirals or columns.
- Push the trays back in and test vend each selection to confirm proper operation.
Programming Prices
- Access the service menu using the VMC (Vending Machine Controller).
- Navigate to Price Setup.
- Assign individual or bulk pricing for selections.
- Save settings and exit the menu.
Customer Interaction
- Customers select products using the keypad.
- The display provides price details and confirms transactions.
Maintenance
Daily Maintenance
- Wipe down the exterior panels and glass with a non-abrasive cloth.
- Check the coin and bill acceptors for debris or jams.
Weekly Maintenance
- Clean condenser coils to ensure efficient refrigeration.
- Test the Sensit sensors for accuracy and recalibrate if necessary.
Monthly Maintenance
- Inspect wiring connections for wear or damage.
- Perform a full diagnostic test using the control board.
Troubleshooting
Issue | Possible Cause | Solution |
Product not vending | Misaligned product or coil jam | Adjust alignment or clear the jam. |
Machine not cooling | Dirty condenser or fan failure | Clean the condenser or replace the fan. |
Sensit system not detecting | Sensor miscalibration | Recalibrate the Sensit system. |
Display not functioning | Loose wiring or power issue | Secure connections and check power supply. |
Contact Information
For technical support, sales, or service inquiries, contact:
- Phone: 304.725.6921
- Fax: 304.725.6983
- Email: [email protected]
For additional resources, visit the AMS Manuals Page.